45° branch pre-insulated bends

Formulas for selection: Hmin = 0,5 x (OD1 + OD2) + 70 [mm] A = √2 x Hmin [mm] Height determined according to table LINK where: OD1 – outer diameter of the main line casing pipe OD2 – outer diameter of the branch casing pipe od1 – outer diameter of the main line steel pipe od2 – outer diameter of the branch steel pipe